T-100 (Triple Output)
Features & Specifications
AC input range selected by switch
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
High reliability,low cost
1 year warranty
|
INDEX TYPE
|
T-100-P1
|
T-100-P2
|
|
DC VOLTAGE
|
5V
|
15V
|
-15V
|
5V
|
12V
|
-24V
|
|
VOLTAGE TOLERANCE
|
±2%
|
±6%
|
±6%
|
±2%
|
±6%
|
±6%
|
|
RATED CURRENT
|
10A
|
2.5A
|
1A
|
6A
|
2A
|
2A
|
|
CURRENT RANGE
|
2-12A
|
0.2-2.5A
|
0.1-1A
|
2-12A
|
0.1-2A
|
0.2-2A
|
|
RIPPLE&NOISE (MAX.)
|
80mVp-p
|
150mVp-p
|
150mVp-p
|
80mVp-p
|
150mVp-p
|
150mVp-p
|
|
LINE REGULATION
|
±0.5%
|
±1%
|
±1%
|
±0.5%
|
±1%
|
±1%
|
|
LOAD REGULATION
|
±1%
|
±5%
|
±5%
|
±1%
|
±5%
|
±5%
|
|
RATED POWER
|
100W
|
102W
|
|
EFFICIENCY
|
77%
|
79%
|
|
VOLTAGE ADJ.RANGE
|
+10,-5%
|
15V
|
-15V
|
+10,-5%
|
12V
|
-24V
|
|
VOLTAGE RANGE
|
85~132VAC/170~264VAC BY SWITCH 47~63Hz
|
|
AC CURRENT
|
2.5A/115V 1.25A/230V
|
|
INRUSH CURRENT (MAX.)
|
cold inrushed current30A/115V 60A/230V
|
|
LEAKAGE CURRENT
|
<0.5mA/240VAC
|
|
OVERLOAD PROTECTION
|
105%~150% recycle AC ON/OFF
|
|
TEMP.COEFFICIENT
|
±0.03%℃(0~50℃) ON+5V OUTPUT
|
|
SETUP.RISE,HOLD TIME
|
200ms,50ms,16ms
|
|
VIBRATION
|
10~500Hz,2G 10min/1cycle,60min,each axes
|
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
|
|
ISOLATED RESISTOR
|
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ
|
|
WORKING TEMP.HUMIDITY
|
-10℃~+60℃,20%~90%RH
|
|
STORAGE TEMP.HUMIDITY
|
-20℃~+85℃,10%~95%RH
|
|
DIMENSION
|
199*110*50mm
|
|
WEIGHT
|
0.83Kgs
|
|
SAFETY STANDARDS
|
To meet UL1012
|
|
EMC
|
EN55022 CLASSB.EN61000-4-2,3,4,5 EN60555-2-3
|
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.