S-500 (Single Output)
Features & Specifications
AC input by switch
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
High reliability,low cost
2 years warranty
| INDEX TYPE |
S-500-12 |
S-500-13.5 |
S-500-15 |
S-500-24 |
S-500-27 |
S-500-48 |
| DC VOLTAGE |
12V |
13.5V |
15V |
24V |
27V |
48V |
| VOLTAGE TOLERANCE |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
| RATED CURRENT |
40A |
36A |
32A |
20A |
18A |
10A |
| CURRENT RANGE |
0-40A |
0-36A |
0-32A |
0-20A |
0-18A |
0-10A |
| RIPPLE&NOISE (MAX.) |
240mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
200mVp-p |
300mVp-p |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| RATED POWER |
480W |
486W |
480W |
480W |
486W |
480W |
| EFFICIENCY |
84% |
84% |
84% |
85.5% |
86% |
87% |
| VOLTAGE ADJ.RANGE |
10-13.2V |
12-15V |
13.5-18V |
20-26.4V |
24-30V |
41-56V |
| VOLTAGE RANGE |
88~264VAC 47-63Hz |
| AC CURRENT |
7A/115V 3.5A/230V |
| INRUSH CURRENT (MAX.) |
18A/115V 36A/230V |
| LEAKAGE CURRENT |
<3.5mA/240VAC |
| OVERLOAD PROTECTION |
105-135% TYPE:Current limitation auto recovery |
| OVERVOLTAGE PROTECTION |
13.8-16.2V |
15.5-18.2V |
18-21V |
27.6-32.4V |
31-36.5V |
57.6-67.2V |
| OVER TEMP. PROTECTION |
≥55℃FAN ON ≤45℃FAN OFF ≥70℃ OUTPUT CUTOUT |
| TEMP.COEFFICIENT |
±0.03%/℃(0~50℃) |
| SETUP.RISE,HOLD TIME |
1.5s,50ms,20ms |
| VIBRATION |
10~500Hz,2G 10min/1cycle,60min,each axes |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC |
| ISOLATED RESISTOR |
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ |
| WORKING TEMP.HUMIDITY |
-10℃~+50℃,20%~90RH |
| STORAGE TEMP.HUMIDITY |
-20℃~+85℃,10%~95%RH |
| DIMENSION |
185×120×93mm |
| WEIGHT |
1.8Kgs |
| COOLING METHOD |
FAN |
| SAFETY STANDARDS |
TO MEET CE,TUV EN60950 |
| EMC |
CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000 |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.