S-350 (Single Output)
Features & Specifications
AC input by switch
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
High reliability,low cost
2 years warranty
| INDEX TYPE |
S-350-12 |
S-350-13.5 |
S-350-15 |
S-350-24 |
S-350-30 |
S-350-48 |
| DC VOLTAGE |
12V |
13.5V |
15V |
24V |
30V |
48V |
| VOLTAGE TOLERANCE |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
| RATED CURRENT |
30A |
25.9A |
23.3A |
14.5A |
11.6A |
7.3A |
| CURRENT RANGE |
0-30A |
0-25.9A |
0-23.3A |
0-14.5A |
0-11.6A |
0-7.3A |
| RIPPLE&NOISE (MAX.) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| RATED POWER |
350W |
350W |
350W |
350W |
350W |
350W |
| EFFICIENCY |
74% |
78% |
80% |
82% |
83% |
84% |
| VOLTAGE ADJ.RANGE |
±10% RATED OUTPUT VOLTAGE |
| VOLTAGE RANGE |
88-132/176-264 BY SWITCH 47-63HZ |
| AC CURRENT |
25A/115V 50A/230V |
| INRUSH CURRENT (MAX.) |
20A/115V 40A/230V |
| LEAKAGE CURRENT |
<3.5mA/240VAC |
| OVERLOAD PROTECTION |
105%~135% HICCUP MODE AUTO-RECOVERY |
| OVERVOLTAGE PROTECTION |
105-145V RATED OUTPUT VOLTAGE |
| OVER TEMP. PROTECTION |
RTH3≥50℃ FAN ON,≤45℃ FAN OFF, ≥80℃ OUTPUT CUTOUT(5 |
| TEMP.COEFFICIENT |
±0.03%℃(0~50℃) |
| SETUP.RISE,HOLD TIME |
2s,20ms,20ms |
| VIBRATION |
10~500Hz,2G 10min/1cycle,60min,each axes |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
| ISOLATED RESISTOR |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ |
| WORKING TEMP.HUMIDITY |
-10℃~+60℃,20%~90%RH |
| STORAGE TEMP.HUMIDITY |
-20℃~+85℃,10%~95%%RH |
| DIMENSION |
215*115*50mm |
| WEIGHT |
1.15Kgs |
| COOLING METHOD |
FAN |
| SAFETY STANDARDS |
TO MEET CE,TUVEN60950 |
| EMC |
EN55022 CLASSB EN61000-4,2,3,4 EN60555-2,3 |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.