S-300 (Single Output)
Features & Specifications
AC input by switch
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
High reliability,low cost
2 years warranty
| INDEX TYPE |
S-300-5 |
S-300-7.5 |
S-300-12 |
S-300-13.5 |
S-300-15 |
S-300-24 |
S-300-48 |
| DC VOLTAGE |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
48V |
| VOLTAGE TOLERANCE |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
| RATED CURRENT |
60A |
42.6A |
25A |
22.2A |
20A |
12.5A |
6.25A |
| CURRENT RANGE |
0-60A |
0-42.6A |
0-25A |
0-22.5A |
0-20A |
0-12.5A |
0-6.25A |
| RIPPLE&NOISE (MAX.) |
150mVp-p |
150mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| RATED POWER |
300W |
300W |
300W |
300W |
300W |
300W |
300W |
| EFFICIENCY |
77% |
80% |
82% |
83% |
85% |
86% |
87% |
| VOLTAGE ADJ.RANGE |
4.5-5.7V |
6-9V |
10-13.2V |
12-15V |
13.5-18V |
20-26.4V |
41-56V |
| VOLTAGE RANGE |
88~132VAC/176~264VAC SELECTED BY SWTCH 4 |
| AC CURRENT |
6A/115V 3.5A/230V |
| INRUSH CURRENT (MAX.) |
20A/115V 40A/230V |
| LEAKAGE CURRENT |
<3.5mA/240VAC |
| OVERLOAD PROTECTION |
105%~135% SHUT DOWN RESET |
| OVERVOLTAGE PROTECTION |
5.75-6.75V |
9.4-10.9V |
13.8-16.2V |
15.5-18.2V |
18-21V |
27.6-32.4V |
57.6-67.2V |
| OVER TEMP. PROTECTION |
RTH1>=65℃ FAN ON<=55℃ FAN OFF>=70℃ SHUT DOWN |
| TEMP.COEFFICIENT |
±0.03%℃(0~50℃) |
| SETUP.RISE,HOLD TIME |
2s,20ms,20ms |
| VIBRATION |
10~500Hz,2G 10min/1cycle,60min,each axes |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
| ISOLATED RESISTOR |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ |
| WORKING TEMP.HUMIDITY |
-10℃~+60℃,20%~90%RH |
| STORAGE TEMP.HUMIDITY |
-20℃~+85℃,10%~95%%RH |
| DIMENSION |
215*115*50mm |
| WEIGHT |
1.15Kgs |
| COOLING METHOD |
| SAFETY STANDARDS |
TO MEET UL1950 TUVEN60950 |
| EMC |
EN55022 CLASSB EN61000-4,2,3,4 EN60555-2,3 |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.