S-200 (Single Output)
Features & Specif ications
AC input range by switch
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
High reliability,low cost
2 years warranty
|
INDEX TYPE
|
S-200-5
|
S-200-7.5
|
S-200-12
|
S-200-13.5
|
S-200-15
|
S-200-24
|
S-200-27
|
S-200-48
|
|
DC VOLTAGE
|
5V
|
7.5V
|
12V
|
13.5V
|
15V
|
24V
|
27V
|
48V
|
|
VOLTAGE TOLERANCE
|
±2%
|
±2%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1% ±1%
|
|
RATED CURRENT
|
40A
|
26.5A
|
16.5A
|
14.7A
|
13A
|
8.3A
|
7.4A
|
4.2A
|
|
CURRENT RANGE
|
0-40A
|
0-26.5A
|
0-16.5A
|
0-14.7A
|
0-13A
|
0-8.3A
|
0-7.4A
|
0-4.2A
|
|
RIPPLE&NOISE (MAX.)
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
240mVp-p
|
|
LINE REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
LOAD REGULATION
|
±1%
|
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
RATED POWER
|
200W
|
200W
|
200W
|
200W
|
200W
|
200W
|
200W
|
200W
|
|
EFFICIENCY
|
74%
|
79%
|
80%
|
81%
|
83%
|
83%
|
85%
|
87%
|
|
VOLTAGE ADJ.RANGE
|
4.5-5.6V
|
6-9V
|
10-13.2V
|
12-15V
|
13.5-18V
|
20-26.4V
|
26-32V
|
41-56V
|
|
VOLTAGE RANGE
|
90~132VAC/180-264VAC 47~63Hz
|
|
AC CURRENT
|
4.5A/115V 2.5A/230V
|
|
INRUSH CURRENT (MAX.)
|
25A/115V 50A/230V
|
|
LEAKAGE CURRENT
|
<3.5mA/240VAC
|
|
OVERLOAD PROTECTION
|
105-145% TYPE:OUTPUT CUTOUT AC Restart
|
|
TEMP.COEFFICIENT
|
±0.03%/℃(0~50℃)
|
|
SETUP.RISE,HOLD TIME
|
200ms,100ms,20ms
|
|
VIBRATION
|
10~500Hz,2G 10min/1cycle,60min,each axes
|
|
WITHSTAND VOLTAGE
|
I/P-O/P:1.5KvACI/P-FG:1.5KvACI/P-FG:0.5KvAC
|
|
ISOLATED RESISTOR
|
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ
|
|
WORKING TEMP.HUMIDITY
|
-10℃~+50℃,20%~90RH
|
|
STORAGE TEMP.HUMIDITY
|
-20℃~+85℃,10%~95%RH
|
|
DIMENSION
|
215×115×50mm
|
|
WEIGHT
|
0.9Kgs
|
|
SAFETY STANDARDS
|
UL1950 TUV60950
|
|
EMC
|
CISPR22(55022),IEC1000-4-2,3,4,5 IEC1000-3-2
|
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.