500W with PFC
Time:2010-1-25 Views:2880
SP-500 (Power Supply with PFC)
|
Features & Specif ications
Universal AC input/Full range
Built-in active PFC function,PF>0.93@230VAC
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
LED indicator for power on.
High reliability,low cost
2 years warranty
|
INDEX TYPE
|
S-500-12
|
S-500-13.5
|
S-500-15
|
S-500-24
|
S-500-48
|
|
DC VOLTAGE
|
12V
|
13.5V
|
15V
|
24V
|
48V
|
|
RATED CURRENT
|
40A
|
36A
|
32A
|
20A
|
10A
|
|
CURRENT RANGE
|
0-40A
|
0-36A
|
0-32A
|
0-20A
|
0-10A
|
|
RIPPLE&NOISE (MAX.)
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
150mVp-p
|
150mVp-p
|
|
LINE REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
LOAD REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
RATED POWER
|
480W
|
486W
|
480W
|
480W
|
480W
|
|
EFFICIENCY
|
84%
|
84%
|
84%
|
85%
|
87%
|
|
VOLTAGE ADJ.RANGE
|
±10%
|
|
VOLTAGE RANGE
|
88~264VAC 47-63Hz
|
|
INRUSH CURRENT
|
18A/115V 36A/230V
|
|
PFC
|
PF>0.96@115VAC,PF>0.93@230VAC
|
|
OVERLOAD PROTECTION
|
105-135% TYPE:Current limitation auto recovery
|
|
OVERVOLTAGE PROTECTION
|
115%-140% rated output voltage
|
|
SETUP.RISE,HOLD TIME
|
1.5s,50ms,20ms
|
|
VIBRATION
|
10~500Hz,2G 10min/1cycle,60min,each axes
|
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC
|
|
ISOLATED RESISTOR
|
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ
|
|
WORKING TEMP.HUMIDITY
|
-10℃~+50℃,20%~90RH
|
|
STORAGE TEMP.HUMIDITY
|
-20℃~+85℃,10%~95%RH
|
|
DIMENSION
|
185×120×93mm
|
|
WEIGHT
|
1.8Kgs
|
|
COOLING METHOD
|
FAN
|
|
SAFETY STANDARDS
|
TO MEET UL60950,EN60950
|
|
EMC
|
CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000
|
|
| |
Note: |
| |
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%. |
|