Product
Contact
Link
|
80W
Time:2010-1-26 Views:3813
| Features & Specif ications |
|
INDEX TYPE
|
SA-80-12
|
SA-80-15
|
SA-80-18
|
SA-80-24
|
SA-18-48
|
|
DC VOLTAGE
|
12VDC
|
15VDC
|
18VDC
|
24VDC
|
48VDC
|
|
VOLTAGE TOLERANCE
|
±4%
|
±3%
|
±3%
|
±2%
|
±2%
|
|
RATED CURRENT
|
6.66A
|
5.33A
|
4.44A
|
3.33A
|
1.66A
|
|
RIPPLE&NOISE (MAX.)
|
100mV
|
100mV
|
120mV
|
150mV
|
240mV
|
|
RATED POWER
|
80W
|
|
EFFICIENCY
|
75%
|
76%
|
77%
|
78%
|
81%
|
|
VOLTAGE RANGE
|
90-264VAC/1.9A,47-63HZ
|
|
AC CURRENT
|
Cold start, <40A peak at 230VAC
|
|
OVERLOAD PROTECTION
|
hiccup mode auto-recovery
|
|
OVERVOLTAGE PROTECTION
|
110-140% rated output voltage
|
|
SETUP.RISE,HOLD TIME
|
16ms at full load
|
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC,1munite
|
|
WORKING TEMP.HUMIDITY
|
0-40℃@100% load, 50℃@70% load
|
|
DIMENSION
|
168X79X45mm
|
|
SAFETY STANDARDS
|
TUV CB CE SAA
|
|
EMC
|
EN55022 CLASSB EN61000-4,2,3,4 EN60555-2,3
|
|
|
|
Note:
|
|
|
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.
|
|